Ludlum Area Radiation Monitors |
|
Ludlum Part Number: 48-4160
Dual Purpose Radiation Frisker/Area Monitor Uses Either Internal or External Detector for Alpha, Beta or Gamma Radiation Supports GM, Scintillation, Proportional Radiation Detectors May be Wall Mounted or Placed on Stand |
Simple Setup/Use, User-Adjustable Alarms
User-Programmable Units of Measure RS-232 Output Data Sheet Product Manual Lumic Calibration Software Manual Options for Model 3000 Series |
Ludlum Part Number: 48-3831
Model 375 Based Digital Area Monitor Internally Mounted 18 mm CsI Scintillation Radiation Detector 0.1 to 9999 µR/hr Range 4-Digit LED Display with 0.8 in. Characters |
Compact, Integrated Design
Audio and Visual Alarms Low Background Sensitivity Battery Backup, Networkable, Optional Remote Data Sheet Product Manual |
Ludlum Part Number: 48-2410
Model 375 Based Digital Area Monitor Internally Mounted Energy Compensated GM Radiation Detector 0.1 mR/hr to 1 R/hr Range 4-Digit LED Display with 0.8 in. Characters |
Compact, Integrated Design
Audio and Visual Alarms Low Background Sensitivity Battery Backup, Networkable, Optional Remote Data Sheet Product Manual |
Ludlum Part Number: 48-2411
Model 375 Based Digital Area Monitor Internally Mounted Energy Compensated GM Radiation Detector 1.0 mR/hr to 10 R/hr Range 4-Digit LED Display with 0.8 in. Characters |
Compact, Integrated Design
Audio and Visual Alarms Low Background Sensitivity Battery Backup, Networkable, Optional Remote Data Sheet Product Manual |
Ludlum Part Number: 48-3560
Model 375 Based Digital Area Radiation Monitor with External Model 45-9 Ion Chamber Radiation Detector Any 4-Decade Range Between 0.1 mR/hr and 1000 R/hr 4-Digit LED Display with 0.8 in. Characters |
Fast Response to Pulsed Fields
Compact, Integrated Design Audio and Visual Alarms Low Background Sensitivity Battery Backup, Networkable, Optional Remote Data Sheet Product Manual |
Ludlum Part Number: 48-3443
Model 375 Based Digital Area Monitor Internally Mounted 2 x 2 in. NaI(Tl) Scintillation Radiation Detector 1 to 2000 µR/hr Range Ideal for Hospitals/Medical Applications Can be Calibrated to be Non-Sensitive to Low Energy Isotopes |
4-Digit LED Display with 0.8 in. Characters
Fast Response to Pulsed Fields Compact, Integrated Design Audio and Visual Alarms Low Background Sensitivity Battery Backup, Networkable, Optional Remote Data Sheet Product Manual |
Ludlum Part Number: 48-3757
Spectroscopic Area Radiation Monitor Internally Mounted 3 x 3 in. NaI Scintillation Detector with an Integral HV Bias Supply Real-Time Isotopic Identification Upon Alarm Multichannel Analyzer, Stand-Alone System NEMA 4x Watertight Enclosure |
Temperature Stabilization
TCP/IP Networking with Automatic Email Notification Sensitivity: 2300 cpm/μR/hr Energy Range: 18 keV to 3 MeV Data Sheet |