Radiation Safety & Protection, LLC


  • Home
  • Ludlum Products
    • New Products
    • Radiation Meters >
      • General Purpose Meters
      • Ion Chambers
      • MicroR Meters
      • Neutron Meters
      • Friskers
      • Isotope Identifiers
      • Data Logging Meters
      • Multi-Detector Meters
      • Telescoping Meters
      • Scaler & Ratemeters
      • Personal Meters & Dosimetry
      • Pocket Meters
      • Benchtop Counters
      • Radiography Meters
      • Intrisically Safe Meters
      • Pulse Generators
      • Meter Accessories
    • Radiation Detectors >
      • Alpha
      • Beta
      • Gamma
      • Alpha/Beta
      • Alpha/Beta/Gamma
      • Beta/Gamma
      • Neutron
      • Pipe Detectors
      • Detector Accessories
    • Sample Counters >
      • Ludlum Alpha/Beta Counters
      • Protean Alpha/Beta Counters
      • Gamma Counters
      • Counter Electronics
      • Counter Heads
      • Sample Holders
      • Sample Planchets
    • Area Monitors >
      • Area Monitors
      • Area Monitor Controllers
      • Area Monitor Accessories
    • Air Monitors >
      • Alpha Beta Air Monitors
      • Tritium Air Monitors
    • Contamination Monitors >
      • Article Monitors
      • Hand & Foot Monitors
      • Portal Monitors
      • Body Monitors
      • Laundry Monitors
      • Floor Monitors
    • Waste Monitors
    • Metal Recycling >
      • Radiation Portal Monitors
      • Conveyor Monitors
      • Bag House Monitors
      • Slug Sample Monitors
      • Handheld Meters
    • Emergency Response >
      • Emergency Response Kits
      • Emergency Portal Monitors
      • Decontamination Kits
    • NORM Meters
    • Medical Physics >
      • Diagnostic Test Tools
      • Mammography Test Tools
      • CT/MRI Phantoms
      • Ultrasound Phantoms
      • Nuclear Medicine
      • Shielding Products
    • Catalogs & Price List
    • Ludlum Support
  • Bladewerx Products
  • Shieldwerx Products
  • Contacts
  • Radiation Resources
    • Radiation In Everyday Life
    • Radiation Safety
    • Radiation Detection & Measurement
    • Emergency Response
    • Government
    • Nuclear Power
    • Medical
    • Metal Recycling & Waste Management
    • Associations & Organizations
    • Journals & Magazines
    • International
    • Health Physics
    • Radiation FAQ's
    • ​Radiation Glossary
    • ​Radiation Abbreviations & Acronyms

Picture

​Ludlum Gamma Radiation Detectors


Picture
Model 44-2
Ludlum Part Number: 47-1532
Low Level Gamma Radiation Survey
1 x 1 in. NaI(Tl) Scintillation Detector
Used with Ludlum General Purpose Radiation Survey Meters, Ratemeters, Scalers
Sensitivity (Cs-137): 175 cpm/µR/hr
Sensitivity (Cs-137): 175 cpm/µR/hr
Energy Range: 50 KeV to 1.5 MeV
Background: 1900 cpm
Efficiency: 7% I-125
Data Sheet
Product Manual
Response Curve
Detector Clips

Picture
Model 44-3
Ludlum Part Number: 47-1533
I-125 Low Energy Gamma Radiation Survey
1 in. x 1 mm thick NaI(Tl) Scintillation Detector
Used with Ludlum General Purpose Radiation Survey Meters, Ratemeters, Scalers
Sensitivity (I-125): 675 cpm/µR/hr
Energy Range: 10 to 60 KeV
​Background: 350 cpm or less
Efficiency: 33.5% I-125 (based on 18% I-129)
Data Sheet
Product Manual
Detector Clips

Picture
Model 44-10
Ludlum Part Number: 47-1540
Low Level Gamma Radiation Survey
2 x 2 in. NaI(Tl) Scintillation Detector
Used with Ludlum General Purpose Radiation Survey Meters, Ratemeters, Scalers
Sensitivity (Cs-137): 900 cpm/µR/hr 
Energy Range: 50 KeV to 3.0 MeV
Background: 9750 cpm
Efficiency: 4.0% for I-125
Data Sheet
Product Manual
Response Curve
Detector Clips

Picture
Model 44-11
Ludlum Part Number: 47-1541
High Sensitivity Gamma Radiation Survey
2 x 2 in. NaI(Tl) Scintillation Detector
MCA Quality, Use with SCA, MCA
Sensitivity (Cs-137): 900 cpm/µR/hr
Energy Range: 50 KeV to 3.0 MeV
Background: 9750 cpm
Data Sheet
Product Manual

Picture
Model 44-17
Ludlum Part Number: 47-1547
I-125 and Low Energy Gamma Survey
2 in. x 2 mm NaI(Tl) Scintillation Detector
Used with Ludlum General Purpose Radiation Survey Meters, Ratemeters, Scalers
Sensitivity (I-125): 2500 cpm/µR/hr
Energy Range: 10 to 200 KeV
​Background: less than 1500 cpm
Efficiency: 41.0% I-125 (based on 22% I-129)
Data Sheet
Product Manual
Response Curve
Detector Clips

Picture
Model 44-20
Ludlum Part Number: 47-1104
High Sensitivity Gamma Radiation Survey
3 x 3 in. NaI(Tl) Scintillation Detector
MCA Quality for Use with SCA, MCA
Sensitivity (Cs-137): 2300 cpm/µR/hr
Background: 23,000 cpm
Efficiency: 29.0% I-125
Replacement Parts
Data Sheet
Product Manual

Picture
Model 44-62
Ludlum Part Number: 47-1238
Low Level Wide-Energy Gamma Survey
0.5 x 1 in. NaI(Tl) Scintillation Detector
Used with Ludlum General Purpose Radiation Survey Meters, Ratemeters, Scalers
Sensitivity (Cs-137): 49 cpm/µR/hr
​Energy Range: 50 KeV to 1.5 MeV
Background: 600 cpm
Data Sheet
Product Manual
Response Curve

Picture
Model 44-132
​Ludlum Part Number: 47-3074
Gamma Survey
5.75 x 1 in. Plastic Scintillation Detector
Sensitivity (Cs-137): 1500 cpm/µR/hr
​​Energy Range: 50 KeV to 1.5 MeV
Background: ≤ 10,000 cpm in a 10 µR/hr field
Data Sheet
Product Manual

Picture
Model 44-159-1
​​Ludlum Part Number: 47-3820
Gamma Survey
0.7 x 0.7 in. CsI (Cesium Iodide) Detector
Sensitivity (Cs-137): 120 cpm/µR/hr
​​​​Dynamic Range: 0 to 5000 µR/hr
​Energy Range: 50 KeV to 3.0 MeV

Data Sheet
Product Manual

Picture
Model 44-183
Ludlum Part Number: 47-3758
Shielded Directional Gamma Radiation Survey and Brac Point Survey
Energy Compensated GM Radiation Detector
10:1 Directional Shielding
Used with Ludlum General Purpose Radiation Survey Meters, Ratemeters, Scalers
Sensitivity: 100 cpm/mR/hr
​Detector Range with DTC: 1 mR/hr to 10 R/hr
Detector Range without DTC: 1 mR/hr to 2 R/hr
Energy Response: ± 15%
Data Sheet
Product Manual
Brac Point Monitor Application Note

Picture
Model 44-213
Ludlum Part Number: 47-4134
Low Energy Gamma Radiation Survey
5 x 0.050 in. FIDLER CsI Scintillation Detector
Used with Ludlum General Purpose Radiation Survey Meters, Ratemeters, Scalers
Efficiency (4π): 13% Am-241; 8% natural U
Energy Range: 10 to 200 KeV
Background: less than 9000 cpm
Window Active Area: 127 cm²
Window Open Area: 127 cm²
Data Sheet

Picture
Model 133-2
Ludlum Part Number: 47-1717
Gamma Radiation Survey, Area Monitoring
Energy Compensated GM Radiation Detector
Used with most Ludlum General Purpose Meters, Ratemeters, Scalers, Area Monitors
Background: 12 cpm (10 μR/h background)
Energy Response: ± 25%
Detector Range with DTC: 0.1 mR/hr to 1 R/hr
​Detector Range without DTC: 0.1 to 200 mR/hr
Sensitivity (Cs-137): 1000 cpm/mR/hr
​​Waterproof Version Available - Model 133-2-1 (Includes 100 ft Detector Cable) P/N 47-2450
Data Sheet
Product Manual
Detector Clips
Response Curve

Picture
Model 133-4
Ludlum Part Number: 47-1674
Gamma Radiation Survey, Area Monitoring
Energy Compensated GM Radiation Detector
Used with most Ludlum General Purpose Meters, Ratemeters, Scalers, Area Monitors
Background: 1 cpm (10 μR/h background)
Energy Response: ± 15%
Sensitivity (Cs-137): 100 cpm/mR/hr
Detector Range with DTC: 1 mR/hr to 10 R/hr
Detector Range without DTC: 1 mR/hr to 2 R/hr​
​Waterproof Version Available - Model 133-4-1 (Includes 100 ft Detector Cable) P/N 47-2451
Data Sheet
Product Manual
Detector Clips

Picture
Model 133-6
Ludlum Part Number: 47-1718
Gamma Radiation Survey, Area Monitoring
Energy Compensated GM Radiation Detector
Used with most Ludlum General Purpose Meters, Ratemeters, Scalers, Area Monitors
Background: 1 cpm (10 μR/h background)
Energy Response: ± 15%
Detector Range with DTC: 4 mR/hr to 40 R/hr
Detector Range without DTC: 4 mR/hr to 6 R/hr
Detector Range with SCC: 4 mR/hr to 1000 R/hr
Sensitivity (Cs-137): 18 cpm/mR/hr
​Waterproof Version Available - Model 133-6-1 (Includes 100 ft Detector Cable) P/N 47-2452
Data Sheet
Product Manual
Detector Clips


         Home          Contacts          Terms & Conditions          Privacy Policy          Disclaimer          
Picture
Radiation Safety & Protection, LLC
6555 Sugarloaf Parkway  Suite 307-333  Duluth, GA 30097
Phone: (770) 363-0925  Email:  sales@radsafetypro.com

                                     Copyright © 2022, Radiation Safety & Protection, LLC  All Rights Reserved